Prevention Surfaces & Positioners

Our Safety Solutions feature comprehensive services and products that improve outcomes. We work collaboratively with providers to assess and fully understand the complications associated with achieving desired results. We work consultatively with all stakeholders to develop and implement programs that eliminate falls, prevent pressure ulcers and dramatically reduce staff injury from manual lifting. We incorporate the latest principles to create a custom formulary that embeds a simple and effective best practice process that delivers results.

PrevaMatt Series

PrevaMatt Ultra

Specifications
Latex free
70-denier cover standard; stretch cover optional
Width options: 35", 36", 37"
Length options: 76", 80", 84"
Depth 7"
Density / ILD:
Tubular foam cylinders - 1.7 lb. / 20 ILD
Perimeter - 1.7 lb. / 55 ILD
Base Layer - 1.7 lb. / 30 ILD
Maximum weight capacity: 400 lbs.
With the optional fire barrier meets or exceeds the highest flammability standards including Federal 16 CFR 1633, Boston Fire Code IX-11, and TB 603
Warranty: 5 years for material defects and workmanship, cover warranties vary
PrevaMatt Ultra Downloads
PrevaMatt Brochure

PrevaMatt Elite w/Tempur

Specifications
Latex free
70-denier cover standard; stretch cover optional
Width options: 35", 36", 37", 39", 42"
Length options: 76", 80", 84"
Depth 6"
Density / ILD:
Tubular foam cylinders - 3.0 lb. / 13 ILD
Perimeter - 1.7 lb. / 55 ILD
Base Layer - 1.7 lb. / 30 ILD
Maximum weight capacity: 500 lbs.
With the optional fire barrier meets or exceeds the highest flammability standards including Federal 16 CFR 1633, Boston Fire Code IX-11, and TB 603
Warranty: 5 years for material defects and workmanship, cover warranties vary
PrevaMatt Elite w/Tempur Downloads
PrevaMatt Brochure
Tempur Brochure

PrevaMatt Deluxe

Specifications
Latex free
70-denier cover standard; stretch cover optional
Width options: 35", 36", 37", 39", 42"
Length options: 76", 80", 84"
Depth 6"
Density / ILD:
Top Layer - 1.7 lb. / 21 ILD
Top Layer Heel (with TEMPUR) - 3.0 lb. / 30 ILD
Perimeter - 1.7 lb. / 55 ILD
Base Layer - 1.7 lb. / 30 ILD
Maximum weight capacity: 500 lbs.
With the optional fire barrier meets or exceeds the highest flammability standards including Federal 16 CFR 1633, Boston Fire Code IX-11, and TB 603
Warranty: 15 years for material defects and workmanship, cover warranties vary
PrevaMatt Deluxe Downloads
PrevaMatt Brochure

PrevaMatt

Specifications
Latex free
70-denier cover standard; stretch cover optional
Width options: 35", 36", 37"
Length options: 76", 80", 84"
Depth 5" or 6"
Density / ILD: 1.5 lb. / 40
Maximum weight capacity: 300 lbs.
With the optional fire barrier meets or exceeds the highest flammability standards including Federal 16 CFR 1633, Boston Fire Code IX-11, and TB 603
Warranty: 2 years for material defects and workmanship, cover warranties vary
PrevaMatt Downloads
PrevaMatt Brochure
Back to Top

ReplaMatt Series

VA Products

Deluxe

Features and Benefits
Mattress Therapy Features

  • Two-ply construction incorporates cross-cut two-inch viscoelastic foam topper to gently cradle head and torso for maximum patient comfort
  • Integrated heel slope provides a gentle tapering of the mattress that redistributes pressure along the lower legs while reducing pressure in the delicate heel section
  • Strategically located articulation cuts in mattress base allow the mattress to move in harmony with the bed frame reducing friction and shear on patient skin and increasing product life cycle
  • Firm perimeter and Tru-fit sizing help meet FDA/HBSW guidelines
  • 70-denier therapy cover with these unique qualities:
  • Fluid proof and stain resistant
  • Infection control treatment
  • Low friction and low shear surface
  • Non-skid bottom prevents mattress sliding on the deck to reduce the risk of falls, is tear resistant
  • Latex free mattress construction

Specifications
Clinical Indications
Pressure redistribution Recommended for prevention and treatment of up to Stage II pressure ulcers.
Technical Specifications
Maximum Weight Capacity* 500 lbs
Mattress
Dimensions 35"(W) x 80"(L) x 7"(D)
36"(W) x 80"(L) x 7"(D)
36"(W) x 84"(L) x 7"(D)
ILD and Density
Top Layer 3.0 lb. / 15 ILD
Top Layer Heel 3.0 lb. / 15 ILD
Perimeter 1.7 lb. / 55 ILD
Base Layer 1.7 lb. / 30 ILD
Flammability Standards
Fire barrier meets fire standards TB 117, TB 129
16 CFR 1633 and BFD IX-11
Warranty: Mattress: 15 years, Cover: One-year
*Mattress weight capacity only; total weight must not exceed bed frame manufacturer’s specified load capacity. Joerns reserves the right to change specifications without notice.

Basic

Features and Benefits
Mattress Therapy Features

  • Firm, yet highly resilient foam, gently cradles head and torso for maximum patient comfort
  • Integrated viscoelastic foam heel slope provides a gentle tapering of the mattress that redistributes pressure along the lower legs while reducing pressure in the delicate heel section
  • Strategically located articulation cuts in mattress base allow the mattress to move in harmony with the bed frame reducing friction and shear on patient skin and increasing product life cycle
  • Firm perimeter and Tru-fit sizing help meet FDA/HBSW guidelines
  • 70-denier therapy cover with these unique qualities:
  • Fluid proof and stain resistant
  • Infection control treatment
  • Low friction and low shear surface
  • Non-skid bottom prevents mattress sliding on the deck to reduce the risk of falls, is tear resistant
  • Latex free mattress construction

Specifications
Clinical Indications
Pressure redistribution Recommended for prevention and treatment of pressure ulcers up to Stage I.
Technical Specifications
Maximum Weight Capacity* 500 lbs
Mattress
Dimensions 35"(W) x 80"(L) x 7"(D)
36"(W) x 80"(L) x 7"(D)
36"(W) x 84"(L) x 7"(D)
ILD and Density
Top Layer 1.7 lb. / 15 ILD
Top Layer Heel 3.0 lb. / 15 ILD
Perimeter 1.7 lb. / 55 ILD
Base Layer 1.7 lb. / 30 ILD
Flammability Standards
Fire barrier meets fire standards TB 117, TB 129
16 CFR 1633 and BFD IX-11
Warranty: Mattress: 15 years, Cover: One-year
*Mattress weight capacity only; total weight must not exceed bed frame manufacturer’s specified load capacity. Joerns reserves the right to change specifications without notice.
Back to Top

BioClinic Series

Non-Powered Products

BioClinic Basic

Prevention of Pressure Ulcers
  • Two-layer construction provides pressure redistribution
  • Precision-cut design top layer
  • 250 lbs. maximum weight capacity
  • 5-year warranty

Specifications
Construction Style
Firm Perimeter (P)
Raised Sidewall (S)
Width: 35"
Length: 76”, 80", 84"
Depth: 6""
Cover
Stretch (SZ)
Nylon (NZ)

BioClinic Deluxe

  • Three-layer, zoned construction provides enhanced pressure redistribution and comfort
  • Integrated viscoelastic heel section
  • 350 lbs. maximum weight capacity
  • 7-year warranty

Specifications
Construction Style
Firm Perimeter (P)
Raised Sidewall (S)
Width: 35", 39", 42"
Length: 76", 80", 84"
Cover: 6"
Cover
Stretch (SZ)
Nylon (NZ)

BioClinic Elite

Prevention - Stage II Pressure Ulcers
  • Four-layer, zoned construction provides excellent
  • pressure redistribution
  • Full length viscoelastic foam topper increases immersion and envelopment
  • 450 lbs. maximum weight capacity
  • 8-year warranty

Specifications
Construction Style
Firm Perimeter (P)
Raised Sidewall (S)
Width: 35", 39", 42"
Length: 76", 80", 84"
Depth: 6"
Cover
Stretch (SZ)
Nylon (NZ)
BioClinic Series Additional Downloads
BioClinic Catalog

Imprint

Specifications
Available with nylon or transverse stretch cover
Non-skid bottom
Widths: 35", 36", or 37"
Lengths: 76", 80", and 84"
Depth: 6"
Maximum weight capacity: 350 lbs.
Meets CAL 117 and 16 CFR 1632; with optional fire barrier meets CAL 129, 16 CFR 1633, BFDIX-11
Warranty: 10 years on foam for material defects and workmanship

DermaTech

Specifications
Nylon
Widths: 35", 36", or 37"
Lengths: 76", 80", and 84"
Depth: 5" or 6"
Maximum weight capacity: 250 lbs. (5" depth), 350 lbs. (6" depth)
Meets CAL 117 and 16 CFR 1632; with optional fire barrier meets TB129, TB603, 16 CFR 1633, BFDIX-11
Warranty: 2 years on foam for material defects and workmanship
Back to Top

P.R.O. Matt Series

P.R.O. Matt Plus

The P.R.O. Matt Plus is a non-powered convertible alternating pressure mattress replacement system featuring our P.R.O. (Pressure Relief Optimization) air control technology. This unique mattress replacement system allows healthcare providers to administer optimal interface pressures through controlled air cell inflation for at-risk residents and treatment of Stage I and II pressure ulcers.

  • The P.R.O. technology system requires no adjustments or manual inflation devices
  • Features a four-zone inner air core that automatically adjusts to meet the needs of each resident based on body profile and weight
Features and Benefits
  • One-inch viscoelastic topper enhances pressure redistribution and patient comfort
  • Optional sidewalls available
  • Surrounding firm perimeter provides stability during patient care and contributes to patient safety by eliminating gaps between frames and siderails
  • Therapy pad with these unique qualities:
    • Fluid proof and stain resistant
    • Low friction and low shear surface
    • Zippered construction
  • Available in multiple widths and lengths
  • Meets flammability standards TB 117, TB 129, 16 CFR 1633 and BFD IX-11
Optional ES2 Control Unit
  • Convert your PRO Matt Plus to alternating pressure therapy to enhance patient comfort and wound healing
  • Three modes of operation – Autofirm, Therapy (static) and Alternate
    • Autofirm assists patients and caregivers during patient transfer and treatment
    • Therapy control settings for eight levels to maximize patient compliance and promote healing
    • Alternating cycle times options of 5, 10 and 15 minutes
  • Closed loop control system eliminates concerns of changes in mattress interface pressure due to patient repositioning and ambient temperature changes
Optional CBC Control Unit
  • Convert your PRO Matt Plus to alternating pressure therapy to enhance patient comfort and wound healing
  • Two modes of operation – Static and Alternate
    • Powered control settings for ten levels to maximize patient compliance and promote healing
    • Pre-set alternating cycle time of 10 minutes
    • Closed loop control system eliminates concerns of changes in mattress interface pressure due to patient repositioning and ambient temperature changes

Specifications
Clinical Indications
Pressure redistribution - Stage I – II Pressure Ulcers*
Pain Management - AIDS; Arthritis; Oncology
*Stage II in non-powered mode and up to uncomplicated Stage III or IV using alternating pressure mode with optional control unit based on individual patient assessment.
Mattress
Four-zone system: head, shoulder, torso, foot
Width: 36" or 42"
Length: 80" or 84"
Height: 7"
Maximum weight capacity: 500 lbs.
Meets fire codes CA 117, CA 129, 16 CFR 1633 and BFD IX-11
Warranty: 5 years, non-prorated
CBC Control Unit
Width: 26"
Height: 13"
Depth: 8"
Weight: 3.5 lbs.
120V AC, 60 Hz
Warranty: 1-year
Back to Top

VA Products

ProCair Series

ProCair Plus

Non-Powered, Convertible Alternating Pressure Therapy System
Featuring P.R.O. Technology
The ProCair Plus is a non-powered convertible alternating pressure mattress replacement system featuring our P.R.O. (Pressure Redistribution Optimization) air control technology. This unique mattress replacement system can be used in either a non-powered mode or with the addition of an optional control unit, it can provide alternating pressure therapy.

Features and Benefits
Mattress Therapy Features
  • Three-zoned system (shoulder, torso and foot) inner air core automatically adjusts to each patient’s body profile and weight
  • P.R.O. Technology valve maintains optimal air pressures in each therapy zone for superior pressure redistribution regardless of patient weight and profile
  • One-inch viscoelastic topper enhances pressure redistribution and patient comfort
  • Optional sidewalls available
  • Surrounding firm perimeter provides stability during patient care and contributes to patient safety by eliminating gaps between frames and siderails
  • Therapy pad with these unique qualities:
    • Fluid proof and stain resistant
    • Low friction and low shear surface
    • Zippered construction
  • Available in multiple widths and lengths
  • Meets flammability standards TB 117, TB 129, 16 CFR 1633 and BFD IX-11
Optional ES Control Unit
  • Convert your ProCair Plus to alternating pressure therapy to enhance patient comfort and wound healing
  • Three alternating pressure zones, including the delicate heel section for optimal pressure redistribution
  • Three modes of operation – Autofirm, Powered (static) and Alternating
    • Autofirm assists patients and caregivers during patient transfer and treatment
    • Powered control settings for eight levels to maximize patient compliance and promote healing
    • Alternating cycle times options of 5, 10 and 15 minutes
  • Closed loop control system eliminates concerns of changes in mattress interface pressure due to patient repositioning and ambient temperature changes

Specifications
Clinical Indications
Pressure redistribution Stage I – II Pressure Ulcers*; Rehabilitation; Burns; Neurology; Dermatology; Amputations
Pain Management AIDS; Arthritis; Oncology
*Stage II in non-powered mode and up to uncomplicated Stage III or IV using alternating pressure mode with optional control unit based on individual patient assessment.
Technical Specifications
Maximum Weight Capacity* 500 lbs
Control Unit
Weight 11 lbs.
Dimensions 13.5"(W) x 9"(H) x 8.5"(D)
Mattress Dimensions
36”(W) x 80”(L) x 7”(D)
36”(W) x 84”(L) x 7”(D)
42”(W) x 80”(L) x 7”(D)
Agency Approvals (ES Control Unit)
UL Classified: UL 60601-1 CAN/CSA C22.2 No. 60601-1
Electrical Specifications (ES Control Unit)
120V AC, 60 Hz, 0.6A
Environmental Conditions
Operating Conditions
Ambient Temperature +10°C to +40°C
Relative Humidity 30% to 75% Non-Condensing
Storage and Shipping Conditions
Ambient Temperature -10°C to +40°C
Relative Humidity 10% to 100%
*Mattress weight capacity only; total weight must not exceed bed frame manufacturer’s specified load capacity. Joerns reserves the right to change specifications without notice.
Warranty: 2-year on mattress, 1-year on cover, electrical components and control unit

ProCair V/VR

Therapeutic Mattress Replacement
The ProCair V and ProCair VR mattress replacement both have a unique cellular design and an ultra-soft Tri-Fill topper to enhance patient comfort and provide exceptional pressure redistribution. The ProCair VR also includes a firm perimeter which provides added stability and safety during patient care and transfer procedures.

Features and Benefits
Mattress Therapy Features
  • Unique longitudinal tubular foam cylinder construction with a high density foam topper for enhanced comfort and pressure redistribution
  • The ProCair VR includes a firm perimeter which provides for added stability and safety during patient care and transfer Psychiatric model available with no zippers, tie-downs or handle straps
  • Integrated heel slope provides a gentle tapering of the mattress that redistributes pressure along the lower legs while reducing pressure in the delicate heel section
  • Ultra-soft Tri-Fill comforter provides added comfort
  • Therapy cover with these unique qualities:
    • Fluid proof and stain resistant
    • Low friction and low shear surface
  • 70-denier zippered cover includes tie downs and handle straps
  • Tear resistant, non-skid bottom prevents mattress sliding on the deck to reduces the risk of falls
  • Latex free mattress construction
  • Available in multiple widths and lengths to meet individual patient needs

Specifications
Technical Specifications
Maximum Weight Capacity* 400 lbs.
Mattress Dimensions
36"(W) x 80"(L) x 7"(D)
36"(W) x 84"(L) x 7"(D)
42"(W) x 80"(L) x 7"(D)
Zipper Cover
360° zipper on 80" mattress
270° zipper on 84" mattress
ILD and Density
Tubular foam cylinders 1.7 lb. / 20 ILD
Perimeter 1.7 lb. / 55 ILD
Base Layer 1.7 lb. / 30 ILD
Flammability Standards
Fire barrier meets fire standards TB 117, TB 129,
16 CFR 1633 and BFD IX-11
Warranty: Mattress: Five-year, Cover: One-year
*Mattress weight capacity only; total weight must not exceed bed frame manufacturer’s specified load capacity. Joerns reserves the right to change specifications without notice.
ProCair V/VR Downloads
ProCair V/VR Specifications

BioClinic Positioners and Overlays

Click here to view BioClinic Positioners and Overlays Back to Top